PZH HGS 100

Code: 7710005

PZH HGS 100

Code: 7710005

HGS100 and HGS100 EB are a separating high power gas discharge tubes intended for equipotential bonding of an installation parts of buildings, which are not interconnected. In case of origin of p.d. (potential diference) between those parts, the high power gas discharge tube ignites and interconnects both parts for a transient time (typical value of internal resistance at startup of HGS100 is 0,001 ÷ 0,002 ?). Recommended installation is inside of the buildings, outdoors, in the damp rooms as well as in the subterraneous areas. For lightning protection equipotential bonding in accordance with IEC 61024-1 as well as for the use in IT - installations in accordance with IEC 60364-5-54.
Weight: 0.25

TECHNICAL DATA AND STANDARDS

LEGEND

MATERIAL


LABEL
MATERIAL
Rf
stainless steel
Rf*H4
acid-resistant stainless steel
Cu
copper
Al
aluminium
Fe
steel
FeZn
galvanized steel
FeZn-H
hot-dip galvanized sheet metal
KFe
polypropylen
FeCu
copper coated steel
Me
brass
PE
polyetilen - UV resistant
N
nylon – UV resistant
P-SV
polyester with UV resistant glass fibres
pvc
electrostatic plastic-coated
PVC
resistant synthetic material
Wood
wood
Concrete
concrete
Ltž
cast iron
CuSn
tinned copper
PP
polypropylen

CONDUCTOR DIMENSIONS

(appropriateness of holders for a certain profile of conductors)

LABEL
DESCRIPTION
Φ

round cross-section conductor

P

rectangular cross-section conductor


CONDUCTOR ATTACHMENT ON FASTENER

LABEL

DESCRIPTION

N

attachment with nylon attachment elements

PE

attachment with polyetilen attachment elements

K
click attachment system
V
screw attachment
*
upon request
Labels legend
HGS100 and HGS100 EB are a separating high power gas discharge tubes intended for equipotential bonding of an installation parts of buildings, which are not interconnected. In case of origin of p.d. (potential diference) between those parts, the high power gas discharge tube ignites and interconnects both parts for a transient time (typical value of internal resistance at startup of HGS100 is 0,001 ÷ 0,002 ?). Recommended installation is inside of the buildings, outdoors, in the damp rooms as well as in the subterraneous areas. For lightning protection equipotential bonding in accordance with IEC 61024-1 as well as for the use in IT - installations in accordance with IEC 60364-5-54.
7710005_PZH_HGS_100_TECHNICAL_DATA_SHEET.pdf