PZH R3 HSAD 16/60VDC S

Code: 7730287

PZH R3 HSAD 16/60VDC S

Code: 7730287

PZH R3 HSAD16/*VDC is a surge arrester designed for DC power supply systems. PZH R3 HSAD16/*VDC contains an improved thermal fuse which ensures timely disconnection of the device from the power grid during overheating and thus prevents damage to the PZH R3 HSAD16/*VDC. Activation of the thermal fuse is signalled by an integral indicator light with the option to utilize its switching contact for remote fault signalling (S). The PZH R3 HSAD16/*VDC is a type T3 two-port surge arrester and has been tested according to standards EN 61643-11 (IEC 61643-11:2011). According to standard EN 62305 (IEC 62305:2010), it is installed in the boundary between zones LPZ 2 - LPZ 3, where it limits induced overvoltage and residual overvoltage in power lines. PZH R3 HSAD16/*VDC are designed to be mounted on a 35 mm DIN rail using a metal clip. Manufacturer’s recommendation: Install the PZH R3 HSAD16/*VDC as close to the device to be protected as possible (no further than 5 m). There must be HERMI’s lightning and surge arrester T1 and T2 installed before the PZH HSAD16/*VDC.

TECHNICAL DATA AND STANDARDS

LEGEND

MATERIAL


LABEL
MATERIAL
Rf
stainless steel
Rf*H4
acid-resistant stainless steel
Cu
copper
Al
aluminium
Fe
steel
FeZn
galvanized steel
FeZn-H
hot-dip galvanized sheet metal
KFe
polypropylen
FeCu
copper coated steel
Me
brass
PE
polyetilen - UV resistant
N
nylon – UV resistant
P-SV
polyester with UV resistant glass fibres
pvc
electrostatic plastic-coated
PVC
resistant synthetic material
Wood
wood
Concrete
concrete
Ltž
cast iron
CuSn
tinned copper
PP
polypropylen

CONDUCTOR DIMENSIONS

(appropriateness of holders for a certain profile of conductors)

LABEL
DESCRIPTION
Φ

round cross-section conductor

P

rectangular cross-section conductor


CONDUCTOR ATTACHMENT ON FASTENER

LABEL

DESCRIPTION

N

attachment with nylon attachment elements

PE

attachment with polyetilen attachment elements

K
click attachment system
V
screw attachment
*
upon request
Labels legend
PZH R3 HSAD16/*VDC is a surge arrester designed for DC power supply systems. PZH R3 HSAD16/*VDC contains an improved thermal fuse which ensures timely disconnection of the device from the power grid during overheating and thus prevents damage to the PZH R3 HSAD16/*VDC. Activation of the thermal fuse is signalled by an integral indicator light with the option to utilize its switching contact for remote fault signalling (S). The PZH R3 HSAD16/*VDC is a type T3 two-port surge arrester and has been tested according to standards EN 61643-11 (IEC 61643-11:2011). According to standard EN 62305 (IEC 62305:2010), it is installed in the boundary between zones LPZ 2 - LPZ 3, where it limits induced overvoltage and residual overvoltage in power lines. PZH R3 HSAD16/*VDC are designed to be mounted on a 35 mm DIN rail using a metal clip. Manufacturer’s recommendation: Install the PZH R3 HSAD16/*VDC as close to the device to be protected as possible (no further than 5 m). There must be HERMI’s lightning and surge arrester T1 and T2 installed before the PZH HSAD16/*VDC.
Mounting method DIN rail (top hat rail) 35 mm
7730287_PZH_R3_HSAD_16_60VDC_S_TECHNICAL_DATA_SHEET.pdf
ISO9001_&_ISO14001_en.pdf
Website name

Contacte

Hermi, d.o.o.

Trnoveljska cesta 15

3000 Celje

Slovenia